Extreme
SCPI Commands :
READ:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme
FETCh:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme
CALCulate:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme
- class ExtremeCls[source]
Extreme commands group definition. 3 total commands, 0 Subgroups, 3 group commands
- class CalculateStruct[source]
Response structure. Fields:
1 Reliability: int: ‘Reliability indicator’
2 Out_Of_Tolerance: int: Out of tolerance result, i.e. the percentage of measurement intervals of the statistic count for spectrum emission measurements exceeding the specified spectrum emission mask limits.
3 Obw: float or bool: Occupied bandwidth
4 Tx_Power_Min: float or bool: Minimum total TX power in the slot
5 Tx_Power_Max: float or bool: Maximum total TX power in the slot
- class ResultData[source]
Response structure. Fields:
1 Reliability: int: ‘Reliability indicator’
2 Out_Of_Tolerance: int: Out of tolerance result, i.e. the percentage of measurement intervals of the statistic count for spectrum emission measurements exceeding the specified spectrum emission mask limits.
3 Obw: float: Occupied bandwidth
4 Tx_Power_Min: float: Minimum total TX power in the slot
5 Tx_Power_Max: float: Maximum total TX power in the slot
- calculate() CalculateStruct[source]
CALCulate:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme
Snippet: value: CalculateStruct = driver.lteMeas.multiEval.seMask.extreme.calculate()
Return the extreme single-value results of the spectrum emission measurement. The values described below are returned by FETCh and READ commands. A CALCulate command returns limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for CalculateStruct structure arguments.
- fetch() ResultData[source]
FETCh:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme
Snippet: value: ResultData = driver.lteMeas.multiEval.seMask.extreme.fetch()
Return the extreme single-value results of the spectrum emission measurement. The values described below are returned by FETCh and READ commands. A CALCulate command returns limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for ResultData structure arguments.
- read() ResultData[source]
READ:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme
Snippet: value: ResultData = driver.lteMeas.multiEval.seMask.extreme.read()
Return the extreme single-value results of the spectrum emission measurement. The values described below are returned by FETCh and READ commands. A CALCulate command returns limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for ResultData structure arguments.