Extreme
SCPI Commands :
READ:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme
FETCh:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme
CALCulate:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme
- class ExtremeCls[source]
Extreme commands group definition. 3 total commands, 0 Subgroups, 3 group commands
- class CalculateStruct[source]
Response structure. Fields:
Reliability: int: ‘Reliability indicator’
Out_Of_Tolerance: int: Out of tolerance result, i.e. the percentage of measurement intervals of the statistic count for spectrum emission measurements exceeding the specified spectrum emission mask limits.
Obw: float or bool: Occupied bandwidth
Tx_Power_Min: float or bool: Minimum total TX power in the slot
Tx_Power_Max: float or bool: Maximum total TX power in the slot
- class ResultData[source]
Response structure. Fields:
Reliability: int: ‘Reliability indicator’
Out_Of_Tolerance: int: Out of tolerance result, i.e. the percentage of measurement intervals of the statistic count for spectrum emission measurements exceeding the specified spectrum emission mask limits.
Obw: float: Occupied bandwidth
Tx_Power_Min: float: Minimum total TX power in the slot
Tx_Power_Max: float: Maximum total TX power in the slot
- calculate() CalculateStruct [source]
# SCPI: CALCulate:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme value: CalculateStruct = driver.lteMeas.multiEval.seMask.extreme.calculate()
Return the extreme single-value results of the spectrum emission measurement. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for CalculateStruct structure arguments.
- fetch() ResultData [source]
# SCPI: FETCh:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme value: ResultData = driver.lteMeas.multiEval.seMask.extreme.fetch()
Return the extreme single-value results of the spectrum emission measurement. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for ResultData structure arguments.
- read() ResultData [source]
# SCPI: READ:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme value: ResultData = driver.lteMeas.multiEval.seMask.extreme.read()
Return the extreme single-value results of the spectrum emission measurement. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for ResultData structure arguments.