Extreme

SCPI Commands :

READ:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme
FETCh:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme
CALCulate:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme
class ExtremeCls[source]

Extreme commands group definition. 3 total commands, 0 Subgroups, 3 group commands

class CalculateStruct[source]

Response structure. Fields:

  • Reliability: int: ‘Reliability indicator’

  • Out_Of_Tolerance: int: Out of tolerance result, i.e. the percentage of measurement intervals of the statistic count for spectrum emission measurements exceeding the specified spectrum emission mask limits.

  • Obw: float or bool: Occupied bandwidth

  • Tx_Power_Min: float or bool: Minimum total TX power in the slot

  • Tx_Power_Max: float or bool: Maximum total TX power in the slot

class ResultData[source]

Response structure. Fields:

  • Reliability: int: ‘Reliability indicator’

  • Out_Of_Tolerance: int: Out of tolerance result, i.e. the percentage of measurement intervals of the statistic count for spectrum emission measurements exceeding the specified spectrum emission mask limits.

  • Obw: float: Occupied bandwidth

  • Tx_Power_Min: float: Minimum total TX power in the slot

  • Tx_Power_Max: float: Maximum total TX power in the slot

calculate() CalculateStruct[source]
# SCPI: CALCulate:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme
value: CalculateStruct = driver.lteMeas.multiEval.seMask.extreme.calculate()

Return the extreme single-value results of the spectrum emission measurement. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.

return:

structure: for return value, see the help for CalculateStruct structure arguments.

fetch() ResultData[source]
# SCPI: FETCh:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme
value: ResultData = driver.lteMeas.multiEval.seMask.extreme.fetch()

Return the extreme single-value results of the spectrum emission measurement. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.

return:

structure: for return value, see the help for ResultData structure arguments.

read() ResultData[source]
# SCPI: READ:LTE:MEASurement<Instance>:MEValuation:SEMask:EXTReme
value: ResultData = driver.lteMeas.multiEval.seMask.extreme.read()

Return the extreme single-value results of the spectrum emission measurement. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.

return:

structure: for return value, see the help for ResultData structure arguments.