Current
SCPI Commands :
READ:LTE:MEASurement<Instance>:MEValuation:SEMask:CURRent
FETCh:LTE:MEASurement<Instance>:MEValuation:SEMask:CURRent
CALCulate:LTE:MEASurement<Instance>:MEValuation:SEMask:CURRent
- class CurrentCls[source]
Current commands group definition. 3 total commands, 0 Subgroups, 3 group commands
- class CalculateStruct[source]
Response structure. Fields:
Reliability: int: ‘Reliability indicator’
Out_Of_Tolerance: int: Out of tolerance result, i.e. the percentage of measurement intervals of the statistic count for spectrum emission measurements exceeding the specified spectrum emission mask limits.
Obw: float or bool: Occupied bandwidth
Tx_Power: float or bool: Total TX power in the slot over all component carriers
- class ResultData[source]
Response structure. Fields:
Reliability: int: ‘Reliability indicator’
Out_Of_Tolerance: int: Out of tolerance result, i.e. the percentage of measurement intervals of the statistic count for spectrum emission measurements exceeding the specified spectrum emission mask limits.
Obw: float: Occupied bandwidth
Tx_Power: float: Total TX power in the slot over all component carriers
- calculate() CalculateStruct [source]
# SCPI: CALCulate:LTE:MEASurement<Instance>:MEValuation:SEMask:CURRent value: CalculateStruct = driver.lteMeas.multiEval.seMask.current.calculate()
Return the current, average and standard deviation single-value results of the spectrum emission measurement. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for CalculateStruct structure arguments.
- fetch() ResultData [source]
# SCPI: FETCh:LTE:MEASurement<Instance>:MEValuation:SEMask:CURRent value: ResultData = driver.lteMeas.multiEval.seMask.current.fetch()
Return the current, average and standard deviation single-value results of the spectrum emission measurement. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for ResultData structure arguments.
- read() ResultData [source]
# SCPI: READ:LTE:MEASurement<Instance>:MEValuation:SEMask:CURRent value: ResultData = driver.lteMeas.multiEval.seMask.current.read()
Return the current, average and standard deviation single-value results of the spectrum emission measurement. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for ResultData structure arguments.