Aclr

SCPI Command :

CONFigure:LTE:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:ACLR
class AclrCls[source]

Aclr commands group definition. 1 total commands, 0 Subgroups, 1 group commands

class AclrStruct[source]

Response structure. Fields:

  • Aclr_Statistics: int: Statistical length in slots

  • Aclr_Enable: bool: Enable or disable the measurement of ACLR results. ON: ACLR results are measured according to the other enable flags in this command. ACLR results for which there is no explicit enable flag are also measured (e.g. power in the assigned E-UTRA channel) . OFF: No ACLR results at all are measured. The other enable flags in this command are ignored.

  • Utra_1_Enable: bool: Enable or disable evaluation of first adjacent UTRA channels.

  • Utra_2_Enable: bool: Enable or disable evaluation of second adjacent UTRA channels.

  • Eutra_Enable: bool: Enable or disable evaluation of first adjacent E-UTRA channels.

get(segment=Segment.Default) AclrStruct[source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:ACLR
value: AclrStruct = driver.configure.lteMeas.multiEval.listPy.segment.aclr.get(segment = repcap.Segment.Default)

Defines settings for ACLR measurements in list mode for segment <no>.

param segment:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Segment’)

return:

structure: for return value, see the help for AclrStruct structure arguments.

set(aclr_statistics: int, aclr_enable: bool, utra_1_enable: bool, utra_2_enable: bool, eutra_enable: bool, segment=Segment.Default) None[source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:ACLR
driver.configure.lteMeas.multiEval.listPy.segment.aclr.set(aclr_statistics = 1, aclr_enable = False, utra_1_enable = False, utra_2_enable = False, eutra_enable = False, segment = repcap.Segment.Default)

Defines settings for ACLR measurements in list mode for segment <no>.

param aclr_statistics:

Statistical length in slots

param aclr_enable:

Enable or disable the measurement of ACLR results. ON: ACLR results are measured according to the other enable flags in this command. ACLR results for which there is no explicit enable flag are also measured (e.g. power in the assigned E-UTRA channel) . OFF: No ACLR results at all are measured. The other enable flags in this command are ignored.

param utra_1_enable:

Enable or disable evaluation of first adjacent UTRA channels.

param utra_2_enable:

Enable or disable evaluation of second adjacent UTRA channels.

param eutra_enable:

Enable or disable evaluation of first adjacent E-UTRA channels.

param segment:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Segment’)