Srs

SCPI Commands :

CONFigure:LTE:MEASurement<Instance>:SRS:VIEW
CONFigure:LTE:MEASurement<Instance>:SRS:TOUT
CONFigure:LTE:MEASurement<Instance>:SRS:REPetition
CONFigure:LTE:MEASurement<Instance>:SRS:SCONdition
CONFigure:LTE:MEASurement<Instance>:SRS:MOEXception
CONFigure:LTE:MEASurement<Instance>:SRS:HDMode
class SrsCls[source]

Srs commands group definition. 8 total commands, 2 Subgroups, 6 group commands

get_hdmode() bool[source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:SRS:HDMode
value: bool = driver.configure.lteMeas.srs.get_hdmode()

Enables or disables the high dynamic mode for power dynamics measurements. With RF path sharing, this command is not applicable.

return:

high_dynamic_mode: No help available

get_mo_exception() bool[source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:SRS:MOEXception
value: bool = driver.configure.lteMeas.srs.get_mo_exception()

Specifies whether measurement results that the CMX500 identifies as faulty or inaccurate are rejected.

return:

meas_on_exception: OFF: Faulty results are rejected. ON: Results are never rejected.

get_repetition() Repeat[source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:SRS:REPetition
value: enums.Repeat = driver.configure.lteMeas.srs.get_repetition()

Specifies the repetition mode of the measurement. The repetition mode specifies whether the measurement is stopped after a single shot or repeated continuously. Use CONFigure:..:MEAS<i>:…:SCOunt to determine the number of measurement intervals per single shot.

return:

repetition: SINGleshot: Single-shot measurement CONTinuous: Continuous measurement

get_scondition() StopCondition[source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:SRS:SCONdition
value: enums.StopCondition = driver.configure.lteMeas.srs.get_scondition()

Qualifies whether the measurement is stopped after a failed limit check or continued. SLFail means that the measurement is stopped and reaches the RDY state when one of the results exceeds the limits.

return:

stop_condition: NONE: Continue measurement irrespective of the limit check. SLFail: Stop measurement on limit failure.

get_timeout() float[source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:SRS:TOUT
value: float = driver.configure.lteMeas.srs.get_timeout()

Defines a timeout for the measurement. The timer is started when the measurement is initiated via a READ or INIT command. It is not started if the measurement is initiated manually. When the measurement has completed the first measurement cycle (first single shot) , the statistical depth is reached and the timer is reset. If the first measurement cycle has not been completed when the timer expires, the measurement is stopped. The measurement state changes to RDY. The reliability indicator is set to 1, indicating that a measurement timeout occurred. Still running READ, FETCh or CALCulate commands are completed, returning the available results. At least for some results, there are no values at all or the statistical depth has not been reached. A timeout of 0 s corresponds to an infinite measurement timeout.

return:

timeout: No help available

get_view() ViewSrs[source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:SRS:VIEW
value: enums.ViewSrs = driver.configure.lteMeas.srs.get_view()

No command help available

return:

view: No help available

set_hdmode(high_dynamic_mode: bool) None[source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:SRS:HDMode
driver.configure.lteMeas.srs.set_hdmode(high_dynamic_mode = False)

Enables or disables the high dynamic mode for power dynamics measurements. With RF path sharing, this command is not applicable.

param high_dynamic_mode:

No help available

set_mo_exception(meas_on_exception: bool) None[source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:SRS:MOEXception
driver.configure.lteMeas.srs.set_mo_exception(meas_on_exception = False)

Specifies whether measurement results that the CMX500 identifies as faulty or inaccurate are rejected.

param meas_on_exception:

OFF: Faulty results are rejected. ON: Results are never rejected.

set_repetition(repetition: Repeat) None[source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:SRS:REPetition
driver.configure.lteMeas.srs.set_repetition(repetition = enums.Repeat.CONTinuous)

Specifies the repetition mode of the measurement. The repetition mode specifies whether the measurement is stopped after a single shot or repeated continuously. Use CONFigure:..:MEAS<i>:…:SCOunt to determine the number of measurement intervals per single shot.

param repetition:

SINGleshot: Single-shot measurement CONTinuous: Continuous measurement

set_scondition(stop_condition: StopCondition) None[source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:SRS:SCONdition
driver.configure.lteMeas.srs.set_scondition(stop_condition = enums.StopCondition.NONE)

Qualifies whether the measurement is stopped after a failed limit check or continued. SLFail means that the measurement is stopped and reaches the RDY state when one of the results exceeds the limits.

param stop_condition:

NONE: Continue measurement irrespective of the limit check. SLFail: Stop measurement on limit failure.

set_timeout(timeout: float) None[source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:SRS:TOUT
driver.configure.lteMeas.srs.set_timeout(timeout = 1.0)

Defines a timeout for the measurement. The timer is started when the measurement is initiated via a READ or INIT command. It is not started if the measurement is initiated manually. When the measurement has completed the first measurement cycle (first single shot) , the statistical depth is reached and the timer is reset. If the first measurement cycle has not been completed when the timer expires, the measurement is stopped. The measurement state changes to RDY. The reliability indicator is set to 1, indicating that a measurement timeout occurred. Still running READ, FETCh or CALCulate commands are completed, returning the available results. At least for some results, there are no values at all or the statistical depth has not been reached. A timeout of 0 s corresponds to an infinite measurement timeout.

param timeout:

No help available

set_view(view: ViewSrs) None[source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:SRS:VIEW
driver.configure.lteMeas.srs.set_view(view = enums.ViewSrs.PDYNamics)

No command help available

param view:

No help available

Cloning the Group

# Create a clone of the original group, that exists independently
group2 = driver.configure.lteMeas.srs.clone()

Subgroups