Current

SCPI Commands :

FETCh:LTE:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:ACLR:CURRent
CALCulate:LTE:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:ACLR:CURRent
class CurrentCls[source]

Current commands group definition. 2 total commands, 0 Subgroups, 2 group commands

class CalculateStruct[source]

Response structure. Fields:

  • Reliability: int: ‘Reliability indicator’

  • Seg_Reliability: int: Reliability indicator for the segment

  • Statist_Expired: int: Reached statistical length in slots

  • Out_Of_Tolerance: int: Percentage of measured subframes with failed limit check

  • Utra_2_Neg: enums.ResultStatus2: ACLR for the second UTRA channel with lower frequency

  • Utra_1_Neg: enums.ResultStatus2: ACLR for the first UTRA channel with lower frequency

  • Eutra_Negativ: enums.ResultStatus2: ACLR for the first E-UTRA channel below the carrier frequency

  • Eutra: enums.ResultStatus2: Power in the allocated E-UTRA channel

  • Eutra_Positiv: enums.ResultStatus2: ACLR for the first E-UTRA channel above the carrier frequency

  • Utra_1_Pos: enums.ResultStatus2: ACLR for the first UTRA channel with higher frequency

  • Utra_2_Pos: enums.ResultStatus2: ACLR for the second UTRA channel with higher frequency

class FetchStruct[source]

Response structure. Fields:

  • Reliability: int: ‘Reliability indicator’

  • Seg_Reliability: int: Reliability indicator for the segment

  • Statist_Expired: int: Reached statistical length in slots

  • Out_Of_Tolerance: int: Percentage of measured subframes with failed limit check

  • Utra_2_Neg: float: ACLR for the second UTRA channel with lower frequency

  • Utra_1_Neg: float: ACLR for the first UTRA channel with lower frequency

  • Eutra_Negativ: float: ACLR for the first E-UTRA channel below the carrier frequency

  • Eutra: float: Power in the allocated E-UTRA channel

  • Eutra_Positiv: float: ACLR for the first E-UTRA channel above the carrier frequency

  • Utra_1_Pos: float: ACLR for the first UTRA channel with higher frequency

  • Utra_2_Pos: float: ACLR for the second UTRA channel with higher frequency

calculate(segment=Segment.Default) CalculateStruct[source]
# SCPI: CALCulate:LTE:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:ACLR:CURRent
value: CalculateStruct = driver.lteMeas.multiEval.listPy.segment.aclr.current.calculate(segment = repcap.Segment.Default)

Return ACLR single value results for segment <no> in list mode. The values described below are returned by FETCh commands. The first four values (reliability to out of tolerance result) are also returned by CALCulate commands. The remaining values returned by CALCulate commands are limit check results, one value for each result listed below.

param segment:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Segment’)

return:

structure: for return value, see the help for CalculateStruct structure arguments.

fetch(segment=Segment.Default) FetchStruct[source]
# SCPI: FETCh:LTE:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:ACLR:CURRent
value: FetchStruct = driver.lteMeas.multiEval.listPy.segment.aclr.current.fetch(segment = repcap.Segment.Default)

Return ACLR single value results for segment <no> in list mode. The values described below are returned by FETCh commands. The first four values (reliability to out of tolerance result) are also returned by CALCulate commands. The remaining values returned by CALCulate commands are limit check results, one value for each result listed below.

param segment:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Segment’)

return:

structure: for return value, see the help for FetchStruct structure arguments.