StandardDev
SCPI Command :
FETCh:LTE:MEASurement<Instance>:MEValuation:LIST:ESFLatness:MINR<nr>:SDEViation
- class StandardDevCls[source]
StandardDev commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- fetch(minRange=MinRange.Default) List[float][source]
FETCh:LTE:MEASurement<Instance>:MEValuation:LIST:ESFLatness:MINR<nr>:SDEViation
Snippet: value: List[float] = driver.lteMeas.multiEval.listPy.esFlatness.minr.standardDev.fetch(minRange = repcap.MinRange.Default)
Return equalizer spectrum flatness single value results (minimum within a range) for all measured list mode segments. The values described below are returned by FETCh commands. A CALCulate command returns limit check results instead, one value for each result listed below.
Suppressed linked return values: reliability
- param minRange:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Minr’)
- return:
minr: Comma-separated list of values, one per measured segment.