StandardDev

SCPI Command :

FETCh:LTE:MEASurement<Instance>:MEValuation:LIST:ESFLatness:DIFFerence<nr>:SDEViation
class StandardDevCls[source]

StandardDev commands group definition. 1 total commands, 0 Subgroups, 1 group commands

fetch(difference=Difference.Default) List[float][source]

FETCh:LTE:MEASurement<Instance>:MEValuation:LIST:ESFLatness:DIFFerence<nr>:SDEViation

Snippet: value: List[float] = driver.lteMeas.multiEval.listPy.esFlatness.difference.standardDev.fetch(difference = repcap.Difference.Default)

Return equalizer spectrum flatness single value results (differences between ranges) for all measured list mode segments. The values described below are returned by FETCh commands. A CALCulate command returns limit check results instead, one value for each result listed below.

Suppressed linked return values: reliability

param difference:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Difference’)

return:

difference: Comma-separated list of values, one per measured segment