Current
SCPI Commands :
FETCh:LTE:MEASurement<Instance>:MEValuation:LIST:ACLR:UTRA<nr>:NEGativ:CURRent
CALCulate:LTE:MEASurement<Instance>:MEValuation:LIST:ACLR:UTRA<nr>:NEGativ:CURRent
- class CurrentCls[source]
Current commands group definition. 2 total commands, 0 Subgroups, 2 group commands
- calculate(utraAdjChannel=UtraAdjChannel.Default) List[ResultStatus2] [source]
# SCPI: CALCulate:LTE:MEASurement<Instance>:MEValuation:LIST:ACLR:UTRA<nr>:NEGativ:CURRent value: List[enums.ResultStatus2] = driver.lteMeas.multiEval.listPy.aclr.utra.negativ.current.calculate(utraAdjChannel = repcap.UtraAdjChannel.Default)
Return the ACLR for the first or second adjacent UTRA channel above (POSitiv) or below (NEGativ) the carrier frequency for all measured list mode segments. The values described below are returned by FETCh commands. CALCulate commands return limit check results instead, one value for each result listed below.
Suppressed linked return values: reliability
- param utraAdjChannel:
optional repeated capability selector. Default value: Ch1 (settable in the interface ‘Utra’)
- return:
utra_negativ: Comma-separated list of values, one per measured segment
- fetch(utraAdjChannel=UtraAdjChannel.Default) List[float] [source]
# SCPI: FETCh:LTE:MEASurement<Instance>:MEValuation:LIST:ACLR:UTRA<nr>:NEGativ:CURRent value: List[float] = driver.lteMeas.multiEval.listPy.aclr.utra.negativ.current.fetch(utraAdjChannel = repcap.UtraAdjChannel.Default)
Return the ACLR for the first or second adjacent UTRA channel above (POSitiv) or below (NEGativ) the carrier frequency for all measured list mode segments. The values described below are returned by FETCh commands. CALCulate commands return limit check results instead, one value for each result listed below.
Suppressed linked return values: reliability
- param utraAdjChannel:
optional repeated capability selector. Default value: Ch1 (settable in the interface ‘Utra’)
- return:
utra_negativ: Comma-separated list of values, one per measured segment