Source code for RsCMPX_LteMeas.Implementations.LteMeas.Prach.Pdynamics.Minimum

from .....Internal.Core import Core
from .....Internal.CommandsGroup import CommandsGroup
from .....Internal.StructBase import StructBase
from .....Internal.ArgStruct import ArgStruct


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs] class MinimumCls: """Minimum commands group definition. 3 total commands, 0 Subgroups, 3 group commands""" def __init__(self, core: Core, parent): self._core = core self._cmd_group = CommandsGroup("minimum", core, parent) # noinspection PyTypeChecker
[docs] class ResultData(StructBase): """Response structure. Fields: \n - Reliability: int: 'Reliability indicator' - Out_Of_Tolerance: int: Out of tolerance result, i.e. the percentage of measurement intervals of the statistic count for power dynamics measurements exceeding the specified power dynamics limits. - Off_Power_Before: float: OFF power mean value for subframe before preamble without transient period. - On_Power_Rms: float: ON power mean value over preamble. - On_Power_Peak: float: ON power peak value within preamble. - Off_Power_After: float: OFF power mean value for subframe after preamble without transient period.""" __meta_args_list = [ ArgStruct.scalar_int('Reliability', 'Reliability'), ArgStruct.scalar_int('Out_Of_Tolerance'), ArgStruct.scalar_float('Off_Power_Before'), ArgStruct.scalar_float('On_Power_Rms'), ArgStruct.scalar_float('On_Power_Peak'), ArgStruct.scalar_float('Off_Power_After')] def __init__(self): StructBase.__init__(self, self) self.Reliability: int = None self.Out_Of_Tolerance: int = None self.Off_Power_Before: float = None self.On_Power_Rms: float = None self.On_Power_Peak: float = None self.Off_Power_After: float = None
[docs] def read(self) -> ResultData: """SCPI: READ:LTE:MEASurement<Instance>:PRACh:PDYNamics:MINimum \n Snippet: value: ResultData = driver.lteMeas.prach.pdynamics.minimum.read() \n Return the current, average, minimum, maximum and standard deviation single-value results of the power dynamics measurement. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below. \n :return: structure: for return value, see the help for ResultData structure arguments.""" return self._core.io.query_struct(f'READ:LTE:MEASurement<Instance>:PRACh:PDYNamics:MINimum?', self.__class__.ResultData())
[docs] def fetch(self) -> ResultData: """SCPI: FETCh:LTE:MEASurement<Instance>:PRACh:PDYNamics:MINimum \n Snippet: value: ResultData = driver.lteMeas.prach.pdynamics.minimum.fetch() \n Return the current, average, minimum, maximum and standard deviation single-value results of the power dynamics measurement. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below. \n :return: structure: for return value, see the help for ResultData structure arguments.""" return self._core.io.query_struct(f'FETCh:LTE:MEASurement<Instance>:PRACh:PDYNamics:MINimum?', self.__class__.ResultData())
# noinspection PyTypeChecker
[docs] class CalculateStruct(StructBase): """Response structure. Fields: \n - Reliability: int: 'Reliability indicator' - Out_Of_Tolerance: int: Out of tolerance result, i.e. the percentage of measurement intervals of the statistic count for power dynamics measurements exceeding the specified power dynamics limits. - Off_Power_Before: float or bool: OFF power mean value for subframe before preamble without transient period. - On_Power_Rms: float or bool: ON power mean value over preamble. - On_Power_Peak: float or bool: ON power peak value within preamble. - Off_Power_After: float or bool: OFF power mean value for subframe after preamble without transient period.""" __meta_args_list = [ ArgStruct.scalar_int('Reliability', 'Reliability'), ArgStruct.scalar_int('Out_Of_Tolerance'), ArgStruct.scalar_float_ext('Off_Power_Before'), ArgStruct.scalar_float_ext('On_Power_Rms'), ArgStruct.scalar_float_ext('On_Power_Peak'), ArgStruct.scalar_float_ext('Off_Power_After')] def __init__(self): StructBase.__init__(self, self) self.Reliability: int = None self.Out_Of_Tolerance: int = None self.Off_Power_Before: float or bool = None self.On_Power_Rms: float or bool = None self.On_Power_Peak: float or bool = None self.Off_Power_After: float or bool = None
[docs] def calculate(self) -> CalculateStruct: """SCPI: CALCulate:LTE:MEASurement<Instance>:PRACh:PDYNamics:MINimum \n Snippet: value: CalculateStruct = driver.lteMeas.prach.pdynamics.minimum.calculate() \n Return the current, average, minimum, maximum and standard deviation single-value results of the power dynamics measurement. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below. \n :return: structure: for return value, see the help for CalculateStruct structure arguments.""" return self._core.io.query_struct(f'CALCulate:LTE:MEASurement<Instance>:PRACh:PDYNamics:MINimum?', self.__class__.CalculateStruct())